Construction Details

Full Construction Details

 Drawing Title (Drawing #)  Download
Full Construction Details Drawings Collection (Packet)

PDF

Assembly Illustrations

 Drawing Title (Drawing #)  Download
Assembly Illustration Drawings Collection (Packet)

PDF
Composite Roof System Cross Section - Mechanically Fastened System (FTR-DMFS1)

PDF | DWG
Composite Roof System Cross Section - Adhered Insulation in Asphalt (FTR-DAS1)

PDF | DWG
Composite Roof System Cross Section - Adhered Insulation in FTR-601 adhesive (FTR-DAS2)

PDF | DWG
Composite Roof System Cross Section - Mechanically Fastened Insulation (FTR-DAS4)

PDF | DWG
Roof System Cross Section - Mechanically Fastened Cover Board and Adhered Insulation (FTR-DAS16SP)

PDF | DWG
Roof System Cross Section - Mechanically Fastened Cover Board and Adhered Insulation with Vapor Barrier (FTR-DAS17SP)

PDF | DWG
Roof System Cross Section - Mechanically Fastened Cover Board and Adhered Insulation with Vapor Barrier (FTR-DAS12SP)

PDF | DWG
Roof System Cross Section - Mechanically Fastened and Adhered Insulation with Vapor Barrier (FTR-DAS13SP)

PDF | DWG
Roof System Cross Section - Mechanically Fastened and Adhered Insulation with Vapor Barrier (FTR-DAS18SP)

PDF | DWG
Composite Roof System Cross Section - Ballasted System (FTR-DBS1)

PDF | DWG

Insulation Attachments

 Drawing Title (Drawing #)  Download
Insulation Attachment Drawings Collection (Packet)

PDF
Preliminary Insulation Attachment for 1-90 Mechanically Attached FiberTite® System (FTR-DI1)

PDF | DWG
Preliminary Attachment - 3/8” Extruded Polystyrene “Cut Fold” Recovery Board (FTR-DI5)

PDF | DWG
Fully Adhered System - Mechanically Attached Insulation, 2” Thickness or Greater (FTR-DI2)

PDF | DWG
Fully Adhered System - Mechanically Attached Insulation, thickness less than 1.5” (FTR-DI3)

PDF | DWG
Fully Adhered System - Mechanically Attached Insulation, 1.5” to 1.9” thickness (FTR-DI4)

PDF | DWG
FTR 601 Insulation Adhesive Application (FTR-D601)

PDF | DWG
Class 1-90 or less M/A Insulation & Membrane Adhered - Field, Perimeter, and Corners (FINS-90a)

PDF | DWG
Class 1-90 M/A Insulation & Adhered Field Membrane - w/ M/A Membrane in Perimeter and Corners (FINS-90b)

PDF | DWG

Sheet Layouts

 Drawing Title (Drawing #)  Download
Sheet Layout Drawings Collection (Packet)

PDF
FTR Magnum Plates and Fasteners - Lap Style and Position (FTR-DLAP)

PDF | DWG
FTR Magnum Plus Plates and Magnum Fasteners - Lap/Placement (FTR-DLAP4)

PDF | DWG
FTR Magnum-2S Plates and Fasteners - Lap/Placement (FTR-DLAP3)

PDF | DWG
Class 1-75 or Less - General Perimeter and Corner Layout (FGL-75)

PDF | DWG
Class 1-90 or Greater - General Perimeter and Corner Layout (FGL-90)

PDF | DWG
Class 1-90 Attachment - 74” Rolls w/ 37” Perimeter Sheets (F74-RG90a)

PDF | DWG
Class 1-90 Attachment - 74” Rolls w/ Strip in Perimeter (F74-RG90b)

PDF | DWG
Class 1-120 Attachment - 74” Rolls w/ 37” Perimeter Sheets (F74-RG120a)

PDF | DWG
Class 1-120 Attachment - 74” Rolls w/ Strip in Perimeter (F74-RG120b)

PDF | DWG
Standard Panels with Tabs - 74” Stock (F74-SP1)

PDF | DWG
Class 1-90 Attachment - Custom Roll w/ Picture Frame (F74-CR90)

PDF | DWG
”Top Sider”  1-165 (F74-TSXX)

PDF | DWG
Class 1-90 Attachment - 100” Rolls w/ 50” Perimeter Rolls (F100-RG90a)

PDF | DWG
Class 1-90 Attachment - 100” Rolls w/ Cover Strip Perimeter (F100-RG90b)

PDF | DWG
Roof System Attachment at Slope Transition and Change in Plane
(FTR-ST1)
PDF | DWG
Roof System Attachment at Slope Transition and Change in Plane - membrane lap alternative (FTR-ST2)

PDF | DWG

Wall Conditions

 Drawing Title (Drawing #)  Download
Wall Condition Drawings Collection (Packet)

PDF
Typical “Membrane” Wall Flashing - Horizontal Blocking w/ Sawcut Reglet (FTR-DW1)

PDF | DWG
Wall Flashing - (Blocking Alternate 1) T-Bar Restraint (FTR-DW1a)

PDF | DWG
Wall Flashing - (Blocking Alternate 2) T-Bar Restraint (FTR-DW1b)

PDF | DWG
Typical “Clad” Metal Wall Flashing - Horizontal Blocking w/ Sawcut Reglet (FTR-DW2)

PDF | DWG
Typical “Clad” Metal Wall Flashing (FTR-DW2i)

PDF | DWG
Wall Flashing - Alternate “Base” Securement (FTR-DW3)

PDF | DWG
Wall Flashing - Alternate Termination’s (FTR-DW4)

PDF | DWG
Wall Flashing - w/ Metal Cap Flashing (FTR-DW5)

PDF | DWG
FiberTite Premanufactured Coping System - Tapered and Non Tapered (FTR-DW5a)

PDF | DWG
Alternate Coping/Flashing (FTR-DW6)

PDF | DWG
Wall Flashing/Inermediate Attachment (FTR-DW7)

PDF | DWG

Edge Conditions

 Drawing Title (Drawing #)  Download
Edge Condition Drawings Collection (Packet)

PDF
Typical Edge Flashing (FTR-DE1)

PDF | DWG
2-Piece Shop Fabricated Metal Edge Flashing (FTR-DE2)

PDF | DWG
Gutter Flashing (FTR-DE3)

PDF | DWG
FiberTite at Fascia System - Standard Fascia Edge (FTR-DE4)

PDF | DWG
FiberTite at Fascia System - Large Fascia Edge (FTR-DE4a)

PDF | DWG
FiberTite at Fascia System - Raised Canted Edge (FTR-DE5)

PDF | DWG
FiberClad Metal “Gravel Stop” Flashing - Ballast Roofing System(s) (FTR-DE6)

PDF | DWG
Gutter Flashing - Ballast Roofing System(s) (FTR-DE7)

PDF | DWG
Architectural Metal Fascia w/ FiberClad Metal Cleat (FTR-DE8)

PDF | DWG
FiberTite 200 Fascia System - Raised Cleat Edge (FTR-DE8a)

PDF | DWG

Penetrations

 Drawing Title (Drawing #)  Download
Penetration Drawings Collection (Packet)

PDF
Typical Wood Curb or Skylight Flashing (FTR-DP1)

PDF | DWG
Typical Wood Curb or Skylight Flashing (isometric view) (FTR-DP1i)

PDF | DWG
Typical Wood or Skylight Curb Flashing - (Blocking Alternate) T-Bar Restraint (FTR-DP1a)

PDF | DWG
Typical Wood or Skylight Curb Flashing - (Blocking Alternate) T-Bar Restraint (isometric view) (FTR-DP1ai)

PDF | DWG
Wood Curb or Skylight Flashing - (Blocking Alternate) T-Bar Restraint (FTR-DP1b)

PDF | DWG
Wood Curb or Skylight Flashing - (Blocking Alternate) T-Bar Restraint (isometric view) (FTR-DP1bi)

PDF | DWG
Insulated Curb or Fire Hatch (FTR-DP2)

PDF | DWG
Pre-Molded Pipe Flashing (FTR-DP3)

PDF | DWG
Pre-Molded Pipe Flashing (isometric view) (FTR-DP3i)

PDF | DWG
Field Fabricated Pipe Flashing (FTR-DP4)

PDF | DWG
Field Fabricated Pipe Flashing (isometric view) (FTR-DP4i)

PDF | DWG
Pitch Pan Flashing (see FTR specifications for conditions on use) (FTR-DP5)

PDF | DWG
Pitch Pan Flashing (isometric view) (see FTR specifications for conditions on use) (FTR-DP5i)

PDF | DWG
Roof Top Stanchion (FTR-DP6)

PDF | DWG
Heated Stack Flashing - w/ Metal Collar (FTR-DP7)

PDF | DWG
Heated Stack Flashing - w/ Metal Collar (isometric view) (FTR-DP7i)

PDF | DWG
Pre-FormedPipe Flashing - Alternate Base Restraint (FTR-DP8)

PDF | DWG
Pre-FormedPipe Flashing - Alternate Base Restraint (isometric view) (FTR-DP8i)

PDF | DWG
Field Fabricated I-Beam Flashing (isometric view) (FTR-DP9i)

PDF | DWG
Field Fabricated Square Tube Flashing (isometric view) (FTR-DP10i)

PDF DWG
Field Fabricated Square Angle Iron Flashing (isometric view) (FTR-DP11i)

PDF | DWG
Typical Drain Flashing (FTR-DD1)

PDF | DWG
Typical Scupper Flashing (FTR-DD2)

PDF | DWG
Typical Drain Flashing - w/ Fleeceback Membrane (FTR-DD3)

PDF | DWG

Expansion Joints and Tie Ins

 Drawing Title (Drawing #)  Download
Expansion Joint and Tie In Drawings Collection (Packet)

PDF
”Low Profile” Expansion Joint (FTR-DX1)

PDF | DWG
Raised Expansion Joint - Over Wood Blocking (FTR-DX2)

PDF | DWG
Raised Expansion Joint - Over Insulation (FTR-DX2a)

PDF | DWG
Raised Expansion Joint - Over Insulation (Ballast System) (FTR-DX2b)

PDF | DWG
Horizontal to Vertical Expansion Joint (FTR-DX3)

PDF | DWG
Flashing “Tie In” - to Existing Roof System(s) (FTR-DT1)

PDF | DWG
FiberClad Metal Flashing “Tie In” - to Existing Roof System(s) (FTR-DT2)

PDF | DWG
Temporary (1 to 2 Years) “Tie In” - to Existing Roof System(s) (FTR-DT3)

PDF | DWG
Temporary “over Night Seal” - to Existing Roof System(s) (FTR-DT4)

PDF | DWG
FiberClad Metal Flashing “Tie In” - to Shingle Roof System(s) (FTR-DT5)

PDF | DWG
Membrane Flashing “Tie In” - to Shingle Roof System(s) (FTR-DT6)

PDF | DWG

Miscellaneous

 Drawing Title (Drawing #)  Download
Miscellaneous Drawings Collection (Packet)

PDF
FTR Protection Pad and Walkway Materials (FTR-DM1)

PDF | DWG
General Base Sheet Attachment (FTR-DM2)

PDF | DWG
Lightning Protection (FTR-DM3)

PDF | DWG
Typical Cover at Membrane T-Laps (T-Joint Cover) (FTR-TLAP)

PDF | DWG
Snow Guard - New Construction (FTR-SGNC)

PDF | DWG
Snow Guard - Retrofit (FTR-SGRF)

PDF | DWG

Induction Welded FiberTite® Systems

 Drawing Title (Drawing #)  Download
Induction Weld Drawings Collection (Packet)

PDF
FTR Induction Weld Plate and FTR Fastener - Proper Installation (FTR-IWS1)

PDF | DWG
Induction Weld Attachment Methods - Class Rating 1-90 & 1-135 (FTR-IWIA1)

PDF | DWG
Induction Weld Field, Perimeter, and Corner - Attachment Designations (FTR-IWIA2)

PDF | DWG
Composite Roof Cross Section - Induction Welded System (FTR-IWMF1)

PDF | DWG
Mechanically Fastened Induction Welded System - Over Metal Retrofit (FTR-IWMR1)

PDF | DWG
Induction Weld Plate Attachment - Layout on Metal Retrofit (FTR-IWMR3)

PDF | DWG
Insulation Attachment - for Metal Retrofit (FTR-MR2)

PDF | DWG

Simulated Metal Roofing

 Drawing Title (Drawing #)  Download
Simulated Metal Roofing Drawings Collection (Packet)

PDF
Composite Roof Cross Section - Simulated Metal Roofing Profile (FTR-SMRP)

PDF | DWG
Ridge and Valley Flashiong - Simulated Metal Roofing Profile (FTR-SMRP1)

PDF | DWG
Simulated Metal Rib Profile Splice - Simulated Metal Rib Profile (FTR-SMRP2)

PDF | DWG

FiberTite® Hybrid™

 Drawing Title (Drawing #)  Download
FiberTite Hybrid Drawings Collection (Packet)

PDF
Multi-Ply Roof System Cross Section - Adhered Insulation in Asphalt (FTR-DAS1MP)

PDF | DWG
Multi-Ply Roof System Cross Section - Adhered Insulation in FTR-601 Adhesive w/ SBS Base (FTR-DAS2MP)

PDF | DWG
Multi-Ply Roof System Cross Section - Adhered Insulation in FTR-601 Adhesive (FTR-DAS3MP)

PDF | DWG
Multi-Ply Roof System Cross Section - Adhered Membrane and Insulation in Asphalt - with Adhered Cover Board in Asphalt (FTR-DAS4MP)

PDF | DWG
Multi-Ply Roof System Cross Section - Adhered Membrane and Insulation in Asphalt w/ SBS Base (FTR-DAS5MP)

PDF | DWG
Multi-Ply Roof System Cross Section - Adhered Membrane and Insulation in FTR-601 Adhesive w/ SBS Base (FTR-DAS6MP)

PDF | DWG
Multi-Ply Roof System Cross Section - Adhered Membrane and Insulation in FTR-601 Adhesive (FTR-DAS7MP)

PDF | DWG
Multi-Ply Roof System Cross Section - Adhered Membrane and Insulation in Asphalt (FTR-DAS8MP)

PDF | DWG
Multi-Ply Roof System Cross Section - Mechanically Fastened Insulation (FTR-DAS9MP)

PDF | DWG
Multi-Ply Roof System Cross Section - Mechanically Fastened Cover Board and Adhered Insulation with Vapor Barrier (FTR-DAS10MP)

PDF | DWG
Multi-Ply Roof System Cross Section - Mechanically Fastened and Adhered Insulation with Vapor Barrier (FTR-DAS11MP)

PDF | DWG
Multi-Ply Roof System Cross Section - Mechanically Fastened Cover Board and Adhered Insulation (FTR-DAS14MP)

PDF | DWG
Multi-Ply Roof System Cross Section - Mechanically Fastened and Adhered Insulation (FTR-DAS15MP)

PDF | DWG
Typical Multi-Ply Drain Flashing (FTR-DP3MP)

PDF | DWG
Typical Multi-Ply Scupper Flashing (FTR-DD2MP)

PDF | DWG
Typical Multi-Ply Curb Base Termination - T-Bar Restraint (FTR-DCB1MP)

PDF | DWG
Typical Multi-Ply Wall Base Termination - T-Bar Restraint (FTR-DWB1MP)

PDF | DWG
Typical Multi-Ply Wall Base Termination - T-Bar Restraint (to FTR Fleeceback)(FTR-DWB2MP)

PDF | DWG
Typical Pre-Molded Multi-Ply Pipe Flashing (FTR-DP3MP)

PDF | DWG
Typical Multi-Ply Field Fabricated Pipe Flashing (FTR-DP4MP)

PDF | DWG

FiberTite® Green

 Drawing Title (Drawing #)  Download
FiberTite Green Drawings Collection (Packet)

PDF
FiberTite Green Vegetated Roof System - Ballast Rock at Drain w/ Edger (FTG-DAED1)

PDF | DWG
FiberTite Green Vegetated Roof System - 4.5” Aluminum Edger at Multilayer (FTG-DAEM1)

PDF | DWG
FiberTite Green Vegetated Roof System - Ballast Rock at Wall w/ Edger (FTG-DAEW1)

PDF | DWG
FiberTite Green Vegetated Roof System - Extensive Multilayer System (FTG-DEML1)

PDF | DWG
FiberTite Green Vegetated Roof System - Standard Multilayer System (FTG-DSML1)

PDF DWG
FiberTite Green Vegetated Roof System - Standard Multilayer System w/ Vector Mapping Mesh (FTG-DSML2)

PDF | DWG
FiberTite Green Vegetated Roof System - FTGVRS Tray System w/ Ballast Rock at Penetration (FTG-DTBP1)

PDF | DWG
FiberTite Green Vegetated Roof System - FTGVRS Tray System w/ Ballast Rock Walkway (FTG-DTBW1)

PDF | DWG
FiberTite Green Vegetated Roof System - FTGVRS Tray System w/ Concrete Paver Walkway (FTG-DTPW1)

PDF | DWG
FiberTite Green Vegetated Roof System - Typical FTGVRS Tray System (FTG-DTRAY1)

PDF | DWG
FiberTite Green Vegetated Roof System - Typical FTGVRS Tray Connection (FTG-DTRAY3)

PDF | DWG
FiberTite Green Vegetated Roof System - Typical FTGVRS Tray Layout (Ballast) (FTG-DTRAY-A)

PDF | DWG
FiberTite Green Vegetated Roof System - Typical FTGVRS Tray Layout (Pavers) (FTG-DTRAY-B)

PDF | DWG
FiberTite Green Vegetated Roof System - Metal Edger and Wall Flashing Profiles (FTG-DTREFL1)

PDF | DWG
FiberTite Green Vegetated Roof System - Irrigation System Layout - Tubing (FTG-DTRIR1)

PDF | DWG
FiberTite Green Vegetated Roof System - Irrigation System Layout - Controls (FTG-DTRIR2)

PDF | DWG
FiberTite Green Vegetated Roof System - Irrigation Connection to Tray (FTG-DTRIR3)

PDF | DWG
FiberTite Green Vegetated Roof System - Irrigation Value Box (FTG-DTRIR4)

PDF | DWG
FiberTite Green Vegetated Roof System - Irrigation Header (FTG-DTRIR5)

PDF | DWG
FiberTite Green Vegetated Roof System - Tray System at Wall (FTG-DTRW1)

PDF | DWG
FiberTite Green Vegetated Roof System - Tray System w/ Ballast Rock at Wall (FTG-DTRW2)

PDF | DWG
FiberTite Green Vegetated Roof System - Ballast Rock at Drain w/ FTVGRS Tray (FTG-DTSD1)

PDF | DWG
FiberTite Green Vegetated Roof System - Ballast Rock at Wall Termination w/ Vector Mapping Mesh (FTG-DVMW1)

PDF | DWG
FiberTite Green Vegetated Roof System - Wall Termination w/ Vector Mapping Mesh (FTG-DVMW2)

PDF | DWG

FiberTite® Brite™ with Kynar®

 Drawing Title (Drawing #)  Download
FiberTite Brite with Kynar Drawings Collection (Packet)

PDF
Typical FiberTite Brite w/ Kynar - Lap Welding (FTR-FTB1)

PDF | DWG
Typical FiberTite Brite w/ Kynar - Butt Welding (FTR-FTB2)

PDF | DWG
Typical Wall Base Flashing - FiberTite Brite w/ Kynar (FTR-FTBW1)

PDF | DWG
Typical Outside and Inside Corner Flashing - FiberTite Brite w/ Kynar (FTR-FTBW2)

PDF | DWG
Typical FiberTite Brite w/ Kynar Membrane - Field Fabricated Pipe Flashing Under Membrane (FTR-FTBP1)

PDF | DWG
Typical FiberTite Brite w/ Kynar Membrane - Field Fabricated Pipe Flashing On Membrane Face (FTR-FTBP2)

PDF | DWG
Typical “Clad” Metal Flashing - FiberTite Brite w/ Kynar Membrane (FTR-KMF1)

PDF | DWG
Typical “Touch Up” on FB-Base Flashing to Match FiberTite Brite w/ Kynar System (FTR-FTBTU)

PDF | DWG
FiberClad Metal Flashing - for FiberTite Brite w/ Kynar System (FTR-FTBE1)

PDF | DWG

11150_Document-Lib-Construct-Dets-V2